Oil/Petroleum TestingMicroscopes & relatedGlassware suppliesScalesMicropipettesAASIonic ChromatographyICP/ICP-MSOrganic(GC, HPLC, GC-MS, LC-MS)European PharmacopeiaAnalyticalLaboratory equipmentsCell CultureAbout usQ&AQuartz cells/labwareCustomized GlasswareBioanalysisContact us

                        

 

 

CLASS B-TMQ.CV 38

 

 60 liters Autoclave

 
CLASS B-TMQ.CV 3850 60L

TMQ.CV Series Table Top Pulsation Steam Vacuum Sterilizer   

 

Main Features:

●Microcomputer control, LCD touch screen;

●Affusion, pulse vacuum, heating, sterilizing, exhaust, vacuum drying the whole process are automatically controlled by program;

●Three times pulsant vacuum: Vcuum up to -0.08MPa, to ensure the efficient exhausting steam of medical dressings, Class A hollow lumen instruments;

●High-performance built-in steam generator and steam-water separator devices, ensure quality steam and without external steam source;

●Pulsation behind vacuum drying system to ensure parcels dry .

●With instruments, instruments bags, dressings, rubber and other sterilization procedures for user's optional;

●With Bowie & Dick and vacuum testing procedures;

●0.22μm HEPA filter can ensure the vacuum steam is amicrobic, to avoid further contamination;

●Dynamically digital display temperature, pressure and time; Text display process status and malfunction alarm;

●Mini printer is optional to real-time record the whole sterilizing process and malfunction informations;

●Beep reminding when finishing sterilization process and malfunction. 

 

Safety Protection:

Over-temperature protection: Over the setting temperature, system automatically cut off power and display alarm;

●Door safety interlock devices: only the doors closed in place, sterilizers to start working procedures. If there is dangerous pressure in the chamber, the door can not be opened;

●Dual overpressure protection: Automatic releasing safety valve. If pressure is over designed , safety valve will open to release; Overpressure automatic protection control. If pressure is over setting, safety valve will automatic release and display alarm;

Anti-dry alarm: below the water level, automatically cut off the heating power and display alarm information;

 Electronic circuit safety devices: AC main circuit with a short-circuit protection, over-voltage DC control circuits with overload protection.

 

Main Technical Parameters:

Designed Pressure: -0.1/0.28MPa           Max. Working Pressure: 0.23MPa         

Pressure Precision: 1KPa       

Sterilization Temperature Range: 105~136 

Temperature Display Precision:  0.1

Temperature uniformity: 0.5 

Chamber Material: SUS304 stainless steel